Pulse Oximeter can detect oxygen saturation and pulse of human blood through finger by photoelectric blood oxygen detection technology combined with volumetric pulse tracing technology. This product is suitable for non-invasive monitoring of blood oxygen saturation and pulse rate in hospitals and families.
Product features:
1) blood oxygen saturation value display
2) pulse rate value and bar chart display
3) pulse waveform display
4) the display mode can be changed
5) the display direction can be changed automatically
6) low battery indication
7) battery voltage low indication: battery voltage low to the point where it can't work normally, battery low indication sign appears
Product performance:
Display mode: 0.96 inch two-color OLED display (blue and yellow)
Display resolution: 128*64
Blood oxygen saturation measurement range: 0% ~ 100%
Error: when the measurement range of blood oxygen saturation is between 70% and 100%, the absolute error is allowed to be ± 2%. Less than 70% undefined.
Pulse rate measurement range: 30bpm (times /min) ~ 250bpm (times /min)
Error: ±2bpm or ±2% for large value.
Pulse rate measurement range: 30bpm ~ 250bpm (resolution: 1bpm)
Accuracy: ±2bpm or ±2% for large value
Measurement range of perfusion index: 0% ~ 20%
Error: when the measurement range of perfusion index is between 1% and 20%, the absolute error is allowed to be ± 1%.
When the measurement range of perfusion index is 0% ~ 0.9%, the allowable absolute error is ± 0.2%.
Resolution: oxygen saturation 1%, pulse rate 1bpm, perfusion index 0.1%
Error under weak perfusion: when the pulse filling degree is 0.4%, the oximeter can correctly display the values of blood oxygen saturation and pulse rate, and the error of blood oxygen saturation is ±4%. The pulse rate error is ±2bpm or ±2%.
Ability to resist ambient light interference: the deviation of blood oxygen measured under indoor natural light and existing lighting source is less than ±1% compared with that under darkroom condition.
Power consumption: no more than 30mA
Working voltage: DC 3.0v
Batteries: 2 no.7 1.5v alkaline batteries
Battery working hours: minimum sustainable working hours of 20 hours, theoretical value of 36 hours
Safety type: BF type application part
The attachment:
◆ one lanyard
◆ one operating manual
please noted:
Smaller orders maybe handled depending on timing, supply and manufacturer. This product is 100% original with certificates - please take care not to purchase fake products.
Pulse Oximeter Product
Details
With real and ture CE certificate
Size: 57mm(L)×31mm(D)×32mm(H)
Weight: 50g